Next: Startup and Shutdown of
Up: OBSERVING WITH THE INT:
Previous: Starting up the INT
See for full details Chapter
.
- TV Camera(s) and Autoguider OFF.
- Press ZP to move telescope to zenith.
- Close PRIMARY and SECONDARY mirror covers IN THAT ORDER.
- Switch over to Engineering Mode.
- Close dome shutters.
- Switch off dome fans; replace covers.
- EXTRACTOR fan off.
- INPUT fan off.
- Close the Finder Cover.
- Move Telescope to Park Access position.
- (Cassegrain only) Replace Primary Mirror Plug.
- (Cassegrain only) Move Telescope to Zenith under computer control.
- Press the EMERGENCYSTOP button.
- Switch Oil Pump OFF.
- Top up the Cryostat(s) with Liquid Nitrogen.
- Check/close dome access doors.
- Close down Telescope Control Software.
- Shutdown ADAM (unless a flatfield is being taken).
- Complete Log Books.