Confirm handover with Duty Technician.
-
Fill the cryostats.
-
If the dome temperature is higher than that
of the outside air, then:
-
Move the dome to azimuth 90 degrees, and open up 1 metre.
-
Check that the EXTRACTOR fan by the telescope base is on, and that the
INPUT fan on the ground floor is on.
-
Read the Telescope Logbook and check INT\?BEWARE documentation for
reported faults or hazards.
-
Check T/S DOME STOP is active.
-
Take ICONA Meteorological readings (optional).
-
Input files of standard stars and target objects into the
PE3220 Telescope Computer (see section
. -
EXTRACTOR fan ON, if not already done.
-
INPUT fan ON, if not already done.
-
Shut all doors and window blinds.
-
White lights out.
-
Remove dome fan covers, if not already done. Dome fans on.
-
Dome access doors closed.
-
Dome lights out.
-
Open Dome fully.
-
Finder cover open.
-
Do a ZEROSET (see section
) -
Primary mirror plug out (Cassegrain focus only).
-
Secondary and primary mirrors open.
-
Telescope in Computer Mode.
-
TV Camera(s) and Autoguider on.
-
Input SET, GUIDE and INCREMENT rates, if other than default values used.
-
Focus the Telescope (see section
or
). -
Do a SNAFU (see section
or
) -
Determine Finder Zero Point