next up previous contents
Next: Notes Up: Detailed description of the Previous: Detailed description of the

Tables

The current best estimates for these parameters are given in Tables 2 - 5 and the associated notes.

 

Configuration Magnitude Focal erεψ0
range length/mm rad
WHT PRIME 6.5 - 14.5 11624.5 +0.001 -1 3.0931
WHT UESPROBE 6.5 - 16.546257+0.0009806-1 -1.5906
INT PRIME 6 - 14 8357 +0.0393+1 4.71239
INT CASS 6 - 14 38216+0.001 +1 3.14159
JKT WFCE 5 - 13 8060 +1.0 -1 6.250
JKT WFCW 5 - 13 8060 +1.0 -1 3.108
JKT CCDE 5 - 12 15000+0.005 +1 0.000
JKT CCDW 5 - 12 15000+0.005 +1 3.141
Table 2: Limiting magnitudes, plate scales and encoder scales (xy systems). 

 

Configuration Magnitude Focal ereθ ε ψ0
range length/mm
WHT CASS 8 - 16 45738 0.001 ±1.745310-5 +1 1.57996
WHT AUXPORT 8 - 16 45738 0.001 ±1.745310-5 +1 1.57996
WHT TAURUS 8 - 16 45738 0.001 ±1.745310-5 +1 -0.01876
Table 3: Limiting magnitudes, plate scales and encoder scales (rθ systems). 

 

Configuration xminxmaxyminymaxx0y0
WHT PRIME 0 110000 0 20000 56401 97417
WHT UESPROBE 0 73600 0 71000 35939 34844
INT PRIME 550 1850 900 1850 512 281
INT CASS 405000 595000 405000 595000 497919 499938
JKT WFCE/W 139.1 240.0 90.8 180.0 142.9 96.9
JKT CCDE/W 1 29200 1 29200 14146 13000
Table 4: Guide probe offsets and limits (xy systems). 

 

Configuration rminrmaxθminθmax x0y0r0
WHT CASS 0 40000 30000 180000 0 0 112040
WHT AUXPORT 0 40000 0 180000 0 0 112040
WHT TAURUS 0 40000 0 180000 0 0 112040
Table 5: Guide probe offsets and limits (rθ systems). 


next up previous contents
Next: Notes Up: Detailed description of the Previous: Detailed description of the

manuals store
Mon Mar 1 17:52:09 GMT 1999