No response on the System Console

 
  1. Proceed to the CLIP Centre.
  2. Check that the correct System Console is selected (Section gif) or set the switch to Control Room, so that the computer can be addressed from the telescope control room. Return to the control room and try DISPLAY DEVICES again.
  3. Otherwise check the computer hardware in the CLIP Centre:
    1. Set the switch to CLIP Centre, for local control.
    2. Check that the disc drive is powered up and is up to speed, and that the computer is powered up (both should have the green ``ready'' lights on their front panels illuminated).
    3. Make sure that the write-protect switch on the disc drive is set to OFF (i.e. unprotected). The switch should be positioned/pressed to the left, and the ``Read Only'' light should be off.
    4. On top of the left-hand module of the PE tex2html_wrap_inline3011 3220 is a long grey box. On this box press the INIT spring-loaded switch. This will `cold' start the computer. If the machine refuses to start, check that the little plastic key is turned to ON and not to STANDBY.
    5. Reboot the computer by answering the questions at the Local Console.

      ENTRY=3

      FILENAME=MSMD3220.LPO (Beware ``0'' and ``O'')

      and wait for the message saying:-

      END OF ENVIRONMENT CONFIGURATION

    6. Reset the switch to Control Room, to transfer control to the INT control room.
    7. Now return to the telescope control room and proceed with Normal Startup (Section gif).