Section 3 : Removing AF2 (1/2)
Telescope Preparation
-
Bring the telescope to access park and fit
the ties.
-
Position rotator with the top mark on AF2
at the top of the rotator.
-
At the PFIP controller on the top end ring
turn both power switches to the off position.
Removal of the Autoguider
-
Turn the power off to the autoguider.
-
Leave the autoguider head fitted to AF2.
-
Remove the autoguider cabling and store
in the autofib cabinet.
-
Remove the autoguider controller and mounting
frame.
Removal of the Fibre Module
-
Put the access platform in place.
-
Disconnect and remove the cabling from AF2
to the telescope top ring connectors. Store in the AF2 cabinet in the dome.
-
Remove the fibre connectors from the telescope
and fit the protective caps.
-
Carefully remove the fibres from the telescope
and lay flat and straight on the dome floor.
-
Remove the swan neck from the telescope
and store in the dome area.
-
Carefully take all the blue science fibres
and coil them in a spiral, starting from the centre to the outside, into
the storage rack on the fibre module.
-
Carefully take the black guide fibre and
coil it in a spiral into the storage rack on the fibre module.
-
Securely tie the fibres into the storage
rack.
-
Using three people, take the weight of the
fibre module and unbolt it.
-
Remove the fibre module, taking care not
to lose the spacers, and put into its storage case with the spacers.
Proceed to Section 4 Removing AF2 part