Terminate the Telescope Control Program by typing on the PE3220 System Console (on the desk to the left of the Engineering Rack):
FINISH
and shut down the Telescope Computer with:
MA MSMD:,OFF
This command shuts down the Telescope Computer to a known state, and leaves the disk protected.
If the observer leaves a flatfield or other calibration exposure running at the end of the night, it is very important that special warning signs are placed on BOTH doors leading into the dome as well as on the console in the Control Room. It is the responsibility of the Telescope Operator to put up these signs, who therefore has to be properly informed by the observer(s). Further, the observer should make sure that, when using a CCD detector, the TO has filled the cryostats with Liquid Nitrogen before starting calibration exposures. The interval between dawn and 09:15 Local Time is reserved for the taking of flat field exposures.
SO
STOPALL
OFF
MA EGLE:,OFF