next up previous contents
Next: CLOSING DOWN THE INT Up: STARTING UP THE INT Previous: Preparation for observing by

Summary

  1. Confirm handover with Duty Technician.
  2. Fill the cryostats.
  3. Check to see if the dome temperature is higher than that of the outside air. If it is then:
    1. Move the dome to azimuth 90 degrees, and open up 1 metre.
    2. Check that the EXTRACTOR fan by the telescope base is on, and that the INPUT fan on the ground floor is on.
  4. Read the Telescope Logbook and check INT\?BEWARE documentation for reported faults or hazards.
  5. Check T/S DOME STOP is active.
  6. Take ICONA Meteorological readings (when the TO has some free time).
  7. Input files of standard stars and target objects into the PE3220 Telescope Computer.
  8. EXTRACTOR fan ON, if not already done.
  9. INPUT fan ON, if not already done.
  10. Shut all doors and window blinds.
  11. White lights out.
  12. Remove dome fan covers, if not already done. Dome fans on.
  13. Dome access doors closed.
  14. Dome lights out.
  15. Open Dome fully.
  16. Finder cover open.
  17. ZEROSET
  18. Primary mirror plug out (Cassegrain focus only).
  19. Secondary and primary mirrors open.
  20. Telescope in Computer Mode.
  21. TV Camera(s) and Autoguider on.
  22. Input SET, GUIDE and INCREMENT rates, if other than default values used.
  23. Focus the Telescope.
  24. SNAFU.
  25. Finder Zero Point



manuals store
Fri Sep 19 14:53:25 BST 1997