Previous: Instrumental parameters
Up: Internal parameters and header information
Next: Plotter parameters
Previous Page: Instrumental parameters
Next Page: Plotter parameters
These consist of some of the defaults used in mask design, and also the
field scale at the mask focal plane.
- SCALE: the image scale at the focal plane of the telescope,
ie. at the mask (arcsec/mm) (The scale at the detector is given by
SCALE FRED)
- MAXSLITLEN: the maximum allowed length of mask slit
on the sky (arcsec)
- MINYMARGIN: the minimum allowed distance between the object
and the ends of the slit (arcsec)
- MINYSEP: the minimum allowed separation between two slits
(arcsec)
- FIDUCDIAM: default diameter of fiducial holes (arcsec)