These consist of some of the defaults used in mask design, and also the
field scale at the mask focal plane.
  - SCALE: the image scale at the focal plane of the telescope,
        ie. at the mask (arcsec/mm) (The scale at the detector is given by 
        SCALE  FRED) FRED)
- MAXSLITLEN: the maximum allowed length of mask slit 
          on the sky (arcsec)
  
- MINYMARGIN: the minimum allowed distance between the object
        and the ends of the slit (arcsec)
  
- MINYSEP: the minimum allowed separation between two slits 
        (arcsec)
  
- FIDUCDIAM: default diameter of fiducial holes (arcsec)