Previous: Mounting CCD filters
Up: No Title
Next: RGO Glass Broad Band Filters (UBVRIZ)
Previous Page: Mounting CCD filters
Next Page: RGO Glass Broad Band Filters (UBVRIZ)

Kitt Peak Interference Filters (BVRI)

These were purchased from Kitt Peak, as originally specified by J Mould. They have flat-topped profiles and are intended for use with CCD detectors (unlike earlier filter systems). Figure F.2 shows details of these filters. Three sets exist; one for the INT, one for the JKT and a spare set at Herstmonceux. The original specifications are given below:

All filters to be 2" x 2", 3mm thick, blocked to 1.1 micron, better than 75% peak transmission (except B 70%), MgF coated, no pinholes, optical quality glass.

R: Filter 7200Å = short-pass hard-coated on 3mm OG590, blocked to 1.1 micron, 75% or better peak transmission, MgF coated on glass side.

I: Filter 9000Å = Short-pass hard-coated on 3mm RG-M9, blocked 1.1 micron, 75% or better peak transmission, MgF coated on glass side.

V: Filter 6000Å = Short-pass hard-coated on 3mm GG 495 blocked to 1.1 micron, 75% or better peak transmission, MgF coated on glass side. (Sent back did not come up to specification, 1/6/81)

B: Filter 4900Å = Short-pass, hard-coated on the glass substrate indicated below, blocked to 1.1 micron, 65% or better peak transmission, MgF2 Coated on glass side. Glass substrate to be cemented combination of Schott GG 385 and either Hoya GM-500 or Hoya C-500 (whichever will adequately suppress the red leak). Total thickness to be 3mm as with the other items.

SIZE: All Filters to be 2 x 2 inches and standard 3mm thickness.

NOTE: All filters to be on optical glass quality and with no pinholes.

Fig. F.2

dxc@mail.ast.cam.ac.uk
Wed Mar 16 03:14:28 GMT 1994