     The PE 3220 control computer is located in the CLIP centre directly
beneath the control room. If there has been a power failure, or the
system has hung up irretrievably it is necessary to initialise the
computer. To do this, and to subsequently bring the computer to life,
follow the instructions given below.
In the CLIP centre ...
-    Find the consolette on top of the 3220 computer rack
     and ensure the 'enable/disable' switch is at 'disable'.   
     Press the INIT button on the consolette and then
     initialize CAMAC crates (see Section 2.5).
In the control room ... 
-    Go to the control computer system terminal in the control room.
     On the screen there should be a list of devices followed by
 
     "Device=". Type C13F. It should respond with:
 
 
     "File=".   Type FX163220.LPO being careful to distinguish between zero and
     letter 'Oh'.
 
 
     Wait for the message END OF ENVIRONMENT CONFIGURATION.
 
-    If the reason for the cold restart was the effects of a power
     failure, then it is advisable at this stage to follow the
     instructions of Section 4.4 on the checking of the CAMAC crates.
-    If things are OK, then you may now join the normal start up
     procedure at step (3) of Section 4.1 or at step (3) in Section 4.2.
-    If the "information display" screen (right most screen in the
     control console) is displaying garbage you will need to reset its
     controller.  This is in the CLIP centre mounted high in the CAMAC
     crate.  It is a blue box with an on/off switch on the back (facing
     you).  Switch it off and on again to reset.
 
 