| Home > Astronomy > Detectors > RED+4 |
Operational Characteristics
|
| Speed | Slow | Fast |
| Bias(ADU) | 3180 | 1210 |
| Gain(e/ADU) | 0.69 |
1.0 |
| Read noise(e) | 4.2 |
5.6 |
| Read noise(ADU) | 6.0 | 5.6 |
| Linear to(ADU) {also see graphs below} |
<1% to 60K |
<1% to 60K |
Readout time (s) binned 1 x 1 |
50 | 39 |
| Readout time(s) binned 2 x 2 | 18 |
15 |
.


Windowing : available with no reduction in performance.
Binning : available with no reduction in performance.
| Vertical CTE | 0.999998 |
| Horizontal CTE | 0.999996 |
| X Pixel size | 15 microns |
| Y Pixel size | 15 microns |
| X size in pixels of digitised area | 4196 |
| Y size in pixels of digitised area | 4112 |
| X size of useful imaging area | 4096 |
| Y size of useful imaging area | 4112 |
| X start of useful imaging area | 50 |
| Ystart of useful imaging area | 1 |
| LN2 capacity of cryostat | 2.5 litres |
| Cryostat window thickness | 5 mm |
| Distance from window to CCD | 10 mm |
| Cryostat window size | 100 mm diameter |
| Flooding type | none |
| Operating temperature | 158K |
| Cool down time | 4 hours see graph |
| Preferred amplifier | F (all are good) |


This graph shows fringing for Red+4 (red) and it's predecessor the WHTWFC (blue).
| Dark current | 6 e/pix/hour |
| Chip flatness | 5 microns peak to valley |
| Back to the top | Back |
|