Autofib 2 STATIC Command

This is an Engineering Interface Engineering Commands and is to be issued at the engineering interface.

STATIC Command
 

Format: STATIC fibno number

fibno = Fibre number
number = Number of times to measure position

Description:  This command gets the robot to measure the position of fibre fibno a total of number times withoutmoving the robot between each measurement.
Results are appended to a file random.dat in the /h0/autofib/logfiles directory. 
Example: Engineering command > static 159 3

For further information refer to the `AF2 Control System Software Manual'.