Section 5 : Fitting the Secondary Mirror
Fitting the Secondary Mirror
-
Crane up to the dome the secondary mirror.
-
Bolt the secondary mirror on to the telescope
and tighten the top two bolts that are used to locate it. DO NOT TOUCH
THE BOTTOM TWO LOCATION BOLTS.
-
Remove the lifting frame.
-
Connect the power supply cable and the three
LVDT cables.
-
Remove the mirror cover.
-
Check that the cabling is secure and pay
particular attention that there is nothing behind the balance weights of
the secondary, as these move in and out during use.
-
Fit the baffle, taking care not to catch
the mirror or trap any cables.
-
Check the area to ensure that there are
no loose components.
Flipping the Top End Ring
-
Release telescope ties when you are sure
telescope is near to balance and slightly bottom end heavy.
-
Turn on the power to the flip ring. The
switch is on the ring.
-
Put the telescope back to zenith.
-
Flip the ring.
-
Bring the telescope back to access park.
-
Turn off the power to the flip ring.
-
Fit the cover to the front of the baffle.
-
Put the telescope back to zenith.
Balance Telescope.
-
Paper calculation on moments removed and
added.
-
Check top to bottom
-
Check across cube
-
Check top to bottom
Testing the Secondary Mirror
-
Turn the power on to the prime focus in
the control room.
-
Using the TCS, move the focus through its
full range using <focus>. The range is 34.5 to115.
-
Using the <page> command in the TCS,
check that the three LVDT's work correctly. These should have a reading
of between -100 and +100.
Final Checks
-
Check that all AF2 cabling and equipment
is accounted for in the AF2 cabinet.
-
Tidy up!
That completes the removal of the AF2 instrument from the telescope.