INGRID DIGIPLAN AMPLIFIER CHASSIS

SK12

   

Amphenol

16-26 Female

SIGNAL NAME

CABLE TYPE

 
       

A

PUPIL STOP A+

 

AMP1 TB1 1A

B

PUPIL STOP A-

 

AMP1 TB1 1B

C

PUPIL STOP B+

 

AMP1 TB1 2A

D

PUPIL STOP B-

 

AMP1 TB1 2B

Chassis GND

MOTOR DRIVE SHIELD

 

N/C

       

E

PUPIL IMAGER A+

 

AMP2 TB1 1A

F

PUPIL IMAGER A-

 

AMP2 TB1 1B

G

PUPIL IMAGER B+

 

AMP2 TB1 2A

H

PUPIL IMAGER B-

 

AMP2 TB1 2B

Chassis GND

MOTOR DRIVE SHIELD

 

N/C

       

J

FOCUS DRIVE A+

 

AMP3 TB1 1A

K

FOCUS DRIVE A-

 

AMP3 TB1 1B

L

FOCUS DRIVE B+

 

AMP3 TB1 2A

M

FOCUS DRIVE B-

 

AMP3 TB1 2B

Chassis GND

MOTOR DRIVE SHIELD

 

N/C

       

N

FILTER WHEEL 1 A+

 

AMP4 TB1 1A

P

FILTER WHEEL 1 A-

 

AMP4 TB1 1B

R

FILTER WHEEL 1 B+

 

AMP4 TB1 2A

S

FILTER WHEEL 1 B-

 

AMP4 TB1 2B

Chassis GND

MOTOR DRIVE SHIELD

 

N/C

       

T

FILTER WHEEL 2 A+

 

AMP5 TB1 1A

U

FILTER WHEEL 2 A-

 

AMP5 TB1 1B

V

FILTER WHEEL 2 B+

 

AMP5 TB1 2A

W

FILTER WHEEL 2 B-

 

AMP5 TB1 2B

Chassis GND

MOTOR DRIVE SHIELD

 

N/C

       

X

     

Y

     

Z

     

a

     

b

MOTOR DRIVE SHIELD

 

Chassis GND

c

     

 

 

 

INGRID DIGIPLAN AMPLIFIER CHASSIS – MOTOR CONTROL

PL13

     

DB37M

SIGNAL NAME

CABLE TYPE

 

1

PUPIL STOP STEP

 

AMP1 SKT2-7

2

PUPIL STOP DIRECTION

 

AMP1 SKT2-5

3

PUPIL STOP ENERGISE

 

AMP1 SKT2-6

32

PUPIL STOP RETURN

 

AMP1 SKT2-8

7

PUPIL IMAGER STEP

 

AMP2 SKT2-7

8

PUPIL IMAGER DIRECTION

 

AMP2 SKT2-5

9

PUPIL IMAGER ENERGISE

 

AMP2 SKT2-6

33

PUPIL IMAGER RETURN

 

AMP2 SKT2-8

13

FOCUS STEP

 

AMP3 SKT2-7

14

FOCUS DIRECTION

 

AMP3 SKT2-5

15

FOCUS ENERGISE

 

AMP3 SKT2-6

34

FOCUS RETURN

 

AMP3 SKT2-8

19

FILTER WHEEL 1 STEP

 

AMP4 SKT2-7

20

FILTER WHEEL 1 DIRECTION

 

AMP4 SKT2-5

21

FILTER WHEEL 1 ENERGISE

 

AMP4 SKT2-6

35

FILTER WHEEL 1 RETURN

 

AMP4 SKT2-8

25

FILTER WHEEL 2 STEP

 

AMP5 SKT2-7

26

FILTER WHEEL 2 DIRECTION

 

AMP5 SKT2-5

27

FILTER WHEEL 2 ENERGISE

 

AMP5 SKT2-6

36

FILTER WHEEL 2 RETURN

 

AMP5 SKT2-8

37

     
       

 

 

INGRID DIGIPLAN AMPLIFIER CHASSIS – MECHANISM STATUS

J1

PL13

   

PL11

 

DB37M

   

Amphenol

16-26 Male

 

4

PUPIL STOP LIMIT+

*

A

 

5

PUPIL STOP LIMIT -

*

B

a

 

PUPIL STOP DATUM IN

 

C

c

6

PUPIL STOP DATUM OUT

   

a

 

PUPIL IMAGER LIMIT+ IN

 

E

c

10

PUPIL IMAGER LIMIT+ OUT

   

a

 

PUPIL IMAGER LIMIT - IN

 

F

c

11

PUPIL IMAGER LIMIT - OUT

   
 

12

PUPIL IMAGER DATUM

*

G

 

16

FOCUS DRIVE LIMIT+

*

J

a

 

FOCUS DRIVE LIMIT – IN

 

K

c

17

FOCUS DRIVE LIMIT - OUT

   

a

 

FOCUS DRIVE DATUM IN

 

L

c

18

FOCUS DRIVE DATUM OUT

   
 

22

FILTER WHEEL 1 LIMIT+

*

N

 

23

FILTER WHEEL 1 LIMIT -

*

P

a

 

FILTER WHEEL 1 DATUM IN

 

R

c

24

FILTER WHEEL 1 DATUM OUT

   
 

28

FILTER WHEEL 2 LIMIT+

*

T

 

29

FILTER WHEEL 2 LIMIT -

*

U

a

 

FILTER WHEEL 2 DATUM IN

 

V

c

30

FILTER WHEEL 2 DATUM OUT

   
       

X

       

Y

       

Z

       

a

1a,c

 

DEBOUNCE VCC (+5v) SUPPLY

   

32a,c

 

DEBOUNCE VDD (gnd) SUPPLY

   

AMP5 SKT2-

DEBOUNCE CLOCK

   

Chassis GND

SENSOR SHIELD WIRES

 

b

AMP1 SKT2-8

PUPIL STOP RETURN

 

D

AMP2 SKT2-8

PUPIL IMAGER RETURN

 

H

AMP3 SKT2-8

FOCUS DRIVE RETURN

 

M

AMP4 SKT2-8

FILTER WHEEL 1 RETURN

 

S

AMP5 SKT2-8

FILTER WHEEL 2 RETURN

 

W

NOTES:-

  1. CONNECTIONS MARKED WITH AN * ARE NOT USED AND MUST BE TIED TO THERE RESPECTIVE RETURNS IN THE CRYOSTAT.

 

INGRID DIGIPLAN AMPLIFIER CHASSIS – DRIVE STATUS

SK14

   

DB50F

SIGNAL NAME

CABLE TYPE

 
       

1

PUPIL STOP AMP FAULT (PORT0 BIT0)

 

AMP1 SKT2-3

2

FILTER 1 AMP FAULT (PORT0 BIT3)

 

AMP4 SKT2-3

3

(PORT0 BIT6)

   

4

(FLAGS BIT0)

   

5

(PORT1 BIT0)

   

6

(PORT1 BIT3)

   

7

(PORT1 BIT6)

   

8

(FLAGS BIT1)

   

9

(PORT2 BIT0)

   

0

(PORT2 BIT3)

   

11

(PORT2 BIT6)

   

12

FLAGS BIT2)

   

13

(PORT3 BIT0)

   

14

(PORT3 BIT3)

   

15

(PORT3 BIT6)

   

16

(FLAGS BIT3)

   

17

GROUND RETURN

   

18

FOCUS AMP DRIVE FAULT (PORT0 BIT2)

 

AMP3 SKT2-3

19

(PORT0 BIT5)

   

20

(INTERUPT REG BIT0)

   

21

GROUND RETURN

   

22

(PORT1 BIT2)

   

23

(PORT1 BIT5)

   

24

(INTERUPT REG BIT1)

   

25

GROUND RETURN

   

26

(PORT2 BIT2)

   

27

(PORT2 BIT5)

   

28

(INTERUPT REG BIT2)

   

29

GROUND RETURN

   

30

(PORT3 BIT2)

   

31

(PORT3 BIT5)

   

32

(INTERUPT REG BIT3)

   

33

GROUND RETURN

   

34

PUPIL IMAGER AMP FAULT (PORT0 BIT1)

 

AMP2 SKT-3

35

FILTER 2 AMP FAULT (PORT0 BIT4)

 

AMP5 SKT2-3

36

(PORT0 BIT7)

   

37

GROUND RETURN

   

38

(PORT1 BIT1)

   

39

(PORT1 BIT4)

   

40

(PORT1 BIT7)

   

41

GROUND RETURN

   

42

(PORT2 BIT1)

   

43

(PORT2 BIT4)

   

44

(PORT2 BIT7)

   

45

GROUND RETURN

   

46

(PORT3 BIT1)

   

47

(PORT3 BIT4)

   

48

(PORT3 BIT7)

   

49

GROUND RETURN

   

50

FAULT RETURNS

 

CHASSIS GND

 

 

INGRID DIGIPLAN AMPLIFIER CHASSIS – POWER CONTROL

PL15

   

DB50M

SIGNAL NAME

CABLE TYPE

 
       

1

PSU CONTROL (PORT4 BIT0)

 

PSU - 24

2

(PORT4 BIT3)

   

3

(PORT4 BIT6)

   

4

(FLAGS BIT4)

   

5

(PORT5 BIT0)

   

6

(PORT5 BIT3)

   

7

(PORT5 BIT6)

   

8

(FLAGS BIT5)

   

9

(PORT6 BIT0)

   

0

(PORT6 BIT3)

   

11

(PORT6 BIT6)

   

12

FLAGS BIT6)

   

13

(PORT7 BIT0)

   

14

(PORT7 BIT3)

   

15

(PORT7 BIT6)

   

16

(FLAGS BIT7)

   

17

GROUND RETURN

   

18

(PORT4 BIT2)

   

19

(PORT4 BIT5)

   

20

(INTERUPT REG BIT4)

   

21

GROUND RETURN

   

22

(PORT5 BIT2)

   

23

(PORT5 BIT5)

   

24

(INTERUPT REG BIT5)

   

25

GROUND RETURN

   

26

(PORT6 BIT2)

   

27

(PORT6 BIT5)

   

28

(INTERUPT REG BIT6)

   

29

GROUND RETURN

   

30

(PORT7 BIT2)

   

31

(PORT7 BIT5)

   

32

(INTERUPT REG BIT7)

   

33

GROUND RETURN

   

34

(PORT4 BIT1)

   

35

(PORT4 BIT4)

   

36

(PORT4 BIT7)

   

37

GROUND RETURN

   

38

(PORT5 BIT1)

   

39

(PORT5 BIT4)

   

40

(PORT5 BIT7)

   

41

GROUND RETURN

   

42

(PORT6 BIT1)

   

43

(PORT6 BIT4)

   

44

(PORT6 BIT7)

   

45

GROUND RETURN

   

46

(PORT7 BIT1)

   

47

(PORT7 BIT4)

   

48

(PORT7 BIT7)

   

49

GROUND RETURN

   

50

PSU CONTROL RETURN

 

CHASSIS GND

 

 

INGRID VME CHASSIS – MOTOR CONTROL

SK18

 

VME8 - P2

DB37F

SIGNAL NAME

CABLE TYPE

64 WAY DIN 41612

1

PUPIL STOP STEP

 

C9

2

PUPIL STOP DIRECTION

 

A10

3

PUPIL STOP ENERGISE

 

C10

4

PUPIL STOP LIMIT+

 

A12

5

PUPIL STOP LIMIT -

 

C11

6

PUPIL STOP DATUM

 

C12

7

PUPIL IMAGER STEP

 

C13

8

PUPIL IMAGER DIRECTION

 

A14

9

PUPIL IMAGER ENERGISE

 

C14

10

PUPIL IMAGER LIMIT+

 

A16

11

PUPIL IMAGER LIMIT -

 

C15

12

PUPIL IMAGER DATUM

 

C16

13

FOCUS STEP

 

C17

14

FOCUS DIRECTION

 

A18

15

FOCUS ENERGISE

 

C18

16

FOCUS DRIVE LIMIT+

 

A20

17

FOCUS DRIVE LIMIT -

 

C19

18

FOCUS DRIVE DATUM

 

C20

19

FILTER WHEEL 1 STEP

 

C1

20

FILTER WHEEL 1 DIRECTION

 

A2

21

FILTER WHEEL 1 ENERGISE

 

C2

22

FILTER WHEEL 1 LIMIT+

 

A4

23

FILTER WHEEL 1 LIMIT -

 

C3

24

FILTER WHEEL 1 DATUM

 

C4

25

FILTER WHEEL 2 STEP

 

C5

26

FILTER WHEEL 2 DIRECTION

 

A6

27

FILTER WHEEL 2 ENERGISE

 

C6

28

FILTER WHEEL 2 LIMIT+

 

A8

29

FILTER WHEEL 2 LIMIT -

 

C7

30

FILTER WHEEL 2 DATUM

 

C8

31

GND

 

A3

32

PUPIL STOP RETURN

 

A7

33

PUPIL IMAGER RETURN

 

A11

34

FOCUS RETURN

 

A15

35

FILTER WHEEL 1 RETURN

 

23A

36

FILTER WHEEL 2 RETURN

 

19A

37

CHASSIS GND

 

CHASSIS

 

 

 

INGRID VME CHASSIS – DRIVE STATUS

PL17

 

XVME-240 JK1

DB50M

SIGNAL NAME

CABLE TYPE

50 WAY HEADER

1

PUPIL STOP AMP FAULT (PORT0 BIT0)

50 WAY FLAT RIBBON

 

2

FILTER 1 AMP FAULT (PORT0 BIT3)

   

3

(PORT0 BIT6)

   

4

(FLAGS BIT0)

   

5

(PORT1 BIT0)

   

6

(PORT1 BIT3)

   

7

(PORT1 BIT6)

   

8

(FLAGS BIT1)

   

9

(PORT2 BIT0)

   

0

(PORT2 BIT3)

   

11

(PORT2 BIT6)

   

12

FLAGS BIT2)

   

13

(PORT3 BIT0)

   

14

(PORT3 BIT3)

   

15

(PORT3 BIT6)

   

16

(FLAGS BIT3)

   

17

GROUND RETURN

   

18

FOCUS AMP DRIVE FAULT (PORT0 BIT2)

   

19

(PORT0 BIT5)

   

20

(INTERUPT REG BIT0)

   

21

GROUND RETURN

   

22

(PORT1 BIT2)

   

23

(PORT1 BIT5)

   

24

(INTERUPT REG BIT1)

   

25

GROUND RETURN

   

26

(PORT2 BIT2)

   

27

(PORT2 BIT5)

   

28

(INTERUPT REG BIT2)

   

29

GROUND RETURN

   

30

(PORT3 BIT2)

   

31

(PORT3 BIT5)

   

32

(INTERUPT REG BIT3)

   

33

GROUND RETURN

   

34

PUPIL IMAGER AMP FAULT (PORT0 BIT1)

   

35

FILTER 2 AMP FAULT (PORT0 BIT4)

   

36

(PORT0 BIT7)

   

37

GROUND RETURN

   

38

(PORT1 BIT1)

   

39

(PORT1 BIT4)

   

40

(PORT1 BIT7)

   

41

GROUND RETURN

   

42

(PORT2 BIT1)

   

43

(PORT2 BIT4)

   

44

(PORT2 BIT7)

   

45

GROUND RETURN

   

46

(PORT3 BIT1)

   

47

(PORT3 BIT4)

   

48

(PORT3 BIT7)

   

49

GROUND RETURN

   

50

FAULT RETURNS

   

 

 

INGRID VME CHASSIS – POWER CONTROL

SK16

 

XVME240 – JK2

DB50F

SIGNAL NAME

CABLE TYPE

50 WAY HEADER

1

PSU CONTROL (PORT4 BIT0)

50 WAY FLAT RIBBON

 

2

(PORT4 BIT3)

   

3

(PORT4 BIT6)

   

4

(FLAGS BIT4)

   

5

(PORT5 BIT0)

   

6

(PORT5 BIT3)

   

7

(PORT5 BIT6)

   

8

(FLAGS BIT5)

   

9

(PORT6 BIT0)

   

0

(PORT6 BIT3)

   

11

(PORT6 BIT6)

   

12

FLAGS BIT6)

   

13

(PORT7 BIT0)

   

14

(PORT7 BIT3)

   

15

(PORT7 BIT6)

   

16

(FLAGS BIT7)

   

17

GROUND RETURN

   

18

(PORT4 BIT2)

   

19

(PORT4 BIT5)

   

20

(INTERUPT REG BIT4)

   

21

GROUND RETURN

   

22

(PORT5 BIT2)

   

23

(PORT5 BIT5)

   

24

(INTERUPT REG BIT5)

   

25

GROUND RETURN

   

26

(PORT6 BIT2)

   

27

(PORT6 BIT5)

   

28

(INTERUPT REG BIT6)

   

29

GROUND RETURN

   

30

(PORT7 BIT2)

   

31

(PORT7 BIT5)

   

32

(INTERUPT REG BIT7)

   

33

GROUND RETURN

   

34

(PORT4 BIT1)

   

35

(PORT4 BIT4)

   

36

(PORT4 BIT7)

   

37

GROUND RETURN

   

38

(PORT5 BIT1)

   

39

(PORT5 BIT4)

   

40

(PORT5 BIT7)

   

41

GROUND RETURN

   

42

(PORT6 BIT1)

   

43

(PORT6 BIT4)

   

44

(PORT6 BIT7)

   

45

GROUND RETURN

   

46

(PORT7 BIT1)

   

47

(PORT7 BIT4)

   

48

(PORT7 BIT7)

   

49

GROUND RETURN

   

50

PSU CONTROL RETURN

 

CHASSIS GND