Commands

ICS command Micro command Descrpition
HELP n/a Online help
help n/a Online help
INFO n/a Online help
info n/a Online help
autoxy <x-posn> <y-posn> <x-posn> XPROBE
<y-posn> YPROBE
Move the autoguider probe in X and Y
autox <x-posn> <x-posn> XPROBE Move the autoguider probe in X (0 to 29,200)
autoy <y-posn> <y-posn> YPROBE Move the autoguider probe in Y (0 to 29,200)
autopark1 <x_posn> XPROBE
<y-posn> YPROBE
Move the autoguider to park position 1
autopark2 <x_posn> XPROBE
<y-posn> YPROBE
Move the autoguider to park position 2
autoprobesetup SETUP XPROBE
SETUP YPROBE
Resets the autoguider probe
autocol <posn> <posn> COLOUR Select colour filter (1 to 8)
coloursetup SETUP COLOUR Resets the neutral density filter
autond <posn> <posn> ND Select Neutral density filter (1 to 8)
ndsetup SETUP ND Resets the neutral density filter
change_filt n/a Edit correspondance table.
status auto XPROBE? NOW
YPROBE? NOW
COLOUR? NOW
ND? NOW
List status of all autoguider mechanisms
mainfiltsetup SETUP MAIN Resets the CCD filter.
mainfilt <posn> <posn> CCD Select CCD filter (1 to 6).
edit_main n/a Edit the filter wheel database and correspondance table
status mainfilt CCD? NOW List the status of the main filter wheel.
tvmirror <in/out> <IN/OUT> FLAT Moves the TV mirror in or out.
tvshutter <open/close> <OPEN/CLOSE> SHUTTER Moves the TV shutter.
tvon IN FLAT
OPEN SHUTTER
Move TV flat in and open TV shutter
tvoff CLOSE SHUTTER
OUT FLAT
Close the TV shutter and move the TV flat out.
status tv FLAT? NOW
SHUTTER? NOW
List the status of all TV mechanisms
detail on/off n/a Include/exclude mechanism statuses and stepper mototr counts from the mimic.


FITS headers

The following FITS headers will be included:

Commands

Keyword variable Descrpition
AGPOSX $gdx Guide star X position
AGYPOS $gdy Guide star y position
JAGFBAND $band Waveband of filter
JAGFPSYS $psys Photometric system of filter
JAGFID $fid Unique ID of filter.


Mimic requirements

  1. In order to make the mimic easy to read, the drawing will reflect the relationship between the elements, rather than their physical positions.
  2. The mimic window is to be as small as possible, after allowing for clarity.
  3. The mechanisms are to be colour coded as follows:
  4. If a warning box is to be displayed at any time, it should be red.
  5. If a filter is in the light beam, the light beam should be drawn in a different colour after the filter. It should be the colour of the filter,if it is not too time-consuming to implement this.
  6. Obsolete mechanisms (the grisms, drift table and hartman shutters) are not to be displayed unless they get out of position.