MULTRUN

This is equivalent to the RUN command, but queues a sequence of exposures with the same exposure time.

Format: MULTRUN <n> <channel> <time> ["

Channel: The name of the data-acquisition channel to be used.

N: The number of exposures in the sequence.

Time: The exposure time in seconds.

Title: A title for the observation.

Examples: multrun pfip 30 60.0 "Time sequence 1"

Queuable: Yes.

Comments: Each exposure is saved to disk in its own file; each is logged as a separate run. Equivalent commands exist for bias, sky etc..