KILLMULT

Stops a sequence of multiple exposures.

Format: KILLMULT <channel>

Channel: The name of the CCD data acquisition channel.

Example: KILLMULT RED

Comments: The current exposure in the series is left to complete normally, and all pending exposures are cancelled. The channel becomes ready for another command when the current exposure completes. KILLMULT can be followed by FINISH or ABORT for a complete stop.